Summary
Functional repair/reinforcement
underwater mortar.
|
|
RE-Underwater Patching Mortar
Product Description
Our underwater patching mortar is used as a non-separate mortar to
conform to structures in the water because of its high density &
durability.
Application
- Piers
- Dams
- Bridges
- Structures in Harbors
- Any Underwater Concrete Structure
- Mixing equipment: Hand mixer.
- Gauge: Scales.
- Application equipment: Underground equipment .
- Insolubility & excellent adhesive performance
- No environmental pollution & non toxic
- Excellent strength manifesting under water
- Workability without molds because it does not flow
Test Results
| Test
Item |
Unit |
Test
Result
|
Test
Method |
1
hour |
3
hours |
1
day |
| Compressive
Strength |
N/mm²
|
13.73 |
27.44 |
42.14 |
KS
F 2476-´02 |
| Adhesive
Strength
|
N/mm²
|
0.98
|
2.45 |
2.94
|
KS
F 2476-´02
|
| Flexural
Strength
|
N/mm²
|
-
|
4.10 |
4.50
|
KS
F 2476-´02
|
| Open
Time
|
Min
|
20
~ 30 minutes |
KS
L 5103-´96
|
Mixing Ratio
| RE-Underwater
Patching Mortar
|
| Type
A
|
Refiner Water
|
| 1
kg
|
160~170 g
|
Directions
- Mix Type A (1 lb.) and Type B (.16 lb.), using a hand mixer.
(refined water may vary depending on temperature and humidity)
- Bring the mixed material wrapped with plastic bag to the underground
site.
- Limit the amount of mixed material at normal temperature so that
it can be applied within 20-30 minutes.
- Dampen concrete surface with refined water before application
to ensure that concrete does not wick away
- moisture from mortar mixture.
- A sufficient curing is required under the temperature below 50°F.
- Do not use if powder hardens.
- Do not apply at temperatures below 31°F.
- Protect the surface from external impact at least for 24 hours
after application, and continue the following work after checking
curing state.
- Refer to instruction on storage of powder or liquid-type material
for further details. If any problems persists, contact the manufacturer.
- Those not instructed in specifications may follow standard concrete
specifications.
- In the event of any discrepancies between the specification and
work environment, please consult the manufacturer or designer before
application.
|